top of page

Characterizing reduced scattering coefficient of normal human skin across different anatomic locations and Fitzpatrick skin types using spatial frequency domain imaging

Phan T et al. Journal of Biomedical Optics. 2021;26(2):026001.

Camo Academy Review

Is skin the same color everywhere? What optical measurements at 10 body sites reveal

Camo Academy Review | Anatomical variation, skin scattering, and scar camouflage

Short answer

Phan and colleagues used patterned-light imaging to estimate how normal skin scatters light at 10 body sites in 15 volunteers spanning Fitzpatrick types I through VI. Differences between people were greatest at shorter wavelengths, where the model had more difficulty separating melanin absorption from scattering. At 851 nanometers, a near-infrared wavelength where that confounding was smaller, estimates still varied by body site. The study supports treating the location of a skin comparison as relevant information. It did not study tattooed scars or show that its measurements are equivalent to visible color. Read the original study.

The question behind a comparison with nearby skin

A scar can look different against skin on the upper arm than a similar-looking mark would against skin on the chest. For an individual, it may also look different beside one part of the surrounding skin than another. These examples illustrate why it is worth saying what someone is comparing, not just naming the person’s general skin tone. They do not mean that a paper on skin optics can dictate which comparison is correct for every scar. The best comparison depends in part on what is being evaluated: how a boundary looks in everyday life, which features a patient notices, or how two regions perform under a defined instrument measurement.

Phan’s group addressed an optical question that is related to that choice but more specific. If normal skin is studied across several sites and in people with different degrees of pigmentation, how much do estimates of reduced scattering vary? And how much of the apparent variation might result from melanin affecting the method used to generate the estimates? The researchers were interested in baseline optical data that could inform later investigations, such as work on burn or wound imaging. They were not testing an aesthetic intervention.

Reduced scattering summarizes how light’s travel is redirected as it interacts with tissue and accounts for whether light tends to keep moving forward. It is separate from absorption, where light is removed from the traveling beam. Skin optics researchers estimate both because they can affect the signal recorded by an instrument in different ways. The contrast in a photograph is an observable result, not a reading of either coefficient. The distinction matters in paramedical tattoo education: an explanatory mechanism is useful only when the evidence actually measures or supports the mechanism.

Study design: wide-field measurements on normal living skin

Fifteen volunteers without known dermatologic complications were studied. Twelve were 18 to 35 years old, and three were 36 to 55. The participants covered Fitzpatrick types I through VI, but the complete range does not imply a large representative sample within every type. The researchers measured each person at ten anatomical locations, including the forehead, cheek, palm, inner and outer forearm, shin, and chest. Measuring several sites per person made within-person comparisons possible. It did not create 150 independent participants. Primary paper, subjects and methods.

The method was spatial frequency domain imaging, or SFDI. Rather than shining an unpatterned light on a spot and recording a single value, the instrument projected regular patterns and measured how those patterns appeared after interacting with skin. A model then estimated optical properties from the recorded images. The researchers selected comparable regions within each site and avoided abrupt curves where artifacts were more likely. This design let them sample an area rather than assuming that one point was representative of all the nearby skin.

The model treated the imaged material as optically uniform within the modeled volume. That is useful for making estimates, but the authors noted that strongly absorbing melanin is localized in the epidermis, not spread throughout the volume in the same way. If the model cannot fully account for that distribution, differences due to absorption can affect inferred scattering. The paper is a good example of why a measurement should not be judged only by how precise its output looks. Confidence also depends on whether the assumptions fit the tissue and wavelength being studied.

What changed with wavelength and location

Across the body locations assessed, variation between participants tended to decline as wavelength increased. In the visible range, where melanin absorption is more prominent, reduced scattering estimates varied more. The authors interpreted the pattern as evidence that epidermal melanin can confound the separation of absorption and scattering in their model. That is not a demonstration that every difference seen at a shorter wavelength is artificial. Nor is it proof that skin with more melanin intrinsically scatters more or less by a fixed amount. The observed value and the researchers’ explanation for part of its variation should remain separate. Results and discussion.

The researchers selected 851 nanometers to examine differences between sites because variation among participants there was smallest in the studied wavelength range. They found meaningful differences across anatomical locations. For example, the reported mean reduced scattering at that wavelength was 1.65 per millimeter for the forehead and 1.28 for the chest. Other sites fell between those values, with overlap and without every pair showing a significant difference. The numbers establish that a single measurement from one body site was not interchangeable with measurements from all the others in this sample.

A near-infrared result is not a color chart for the visible spectrum. In this case, the wavelength helped the researchers compare scattering with less influence from melanin absorption under their measurement conditions. A client does not judge an everyday color match at this wavelength alone. The practical interpretation is that the choice of reference site can matter even when a source of variation associated with the measurement method is reduced. It is not that an artist should use those values to pick a color or that the lower number identifies a better treatment site.

What the paper does not show about scar camouflage

The study was done on normal skin, not burn scars, stretch marks, or reconstructed skin. It does not establish what happens to the optical results when a scar is present or how implanted color changes the measurements. A controlled comparison of normal body sites provides a useful baseline. A useful baseline is not a substitute for observations of the tissue and outcome of interest. If a paper never measured treated scars, it cannot tell us whether patients found their scars less noticeable after camouflage.

Fitzpatrick type also needs to be read in context. It is a classification tied to sun response, not a precise optical or color coordinate. A study can use it to describe its volunteers and still leave important questions about the tones and anatomical variation within each category. In addition, the range of types in this study does not remove the limits of working with just 15 individuals. The paper is informative about a wavelength-dependent measurement problem and illustrates site variation; it does not supply a table of universal values for each skin tone.

The comparisons between body regions were obtained with a particular instrument and modeling approach. They do not say that a scar on one site will heal better than a scar on another, that one shade will match every part of a site, or that photographic conditions can be corrected by applying a reported coefficient. Those are attractive shortcuts because they turn a research statistic into a clear instruction. They also change the question. The paper demonstrates that site and method are part of the answer to an optical research problem, not that they determine individual treatment choices.

Camo Academy interpretation

We read this as a good argument for putting the reference region in the record. “Compared with surrounding skin at the same site” is a more informative statement than “matches the patient’s tone,” particularly when only one photo is being discussed. A person’s general complexion may help frame an educational discussion, but it is not a complete description of what an observer sees at one body site. If the question is whether a scar stands out, the relationship between that site and its immediate context is usually what the client wants to talk about.

A second implication is about the limits of visually naming a cause. A reviewer might say a scar looks more noticeable toward a curved edge. The image describes that observation; it does not show whether geometry, underlying scattering, the illumination, the color difference, or several factors contribute. Teaching the distinction strengthens the review rather than weakening it. It is possible to describe a visible difference plainly, acknowledge its importance, and still explain that the mechanism is unmeasured.

We also see a useful research question the paper leaves open. Are camouflage outcome records more informative when the comparison area and viewing conditions are explicitly defined and held consistent across time? That is a reasonable hypothesis to test with actual camouflage cases and patient feedback. It is not a finding of this normal-skin study. The difference is worth preserving: an article can inspire a better design without already proving the result we hope the design will help us understand.

Two applied examples

A reference photo shows a different part of the body

A student uses a photograph of the inner forearm to describe a person’s general coloring while evaluating a scar on the upper chest. The forearm photo may be useful context, but it does not document the skin beside the chest scar. Rather than infer that the two sites are optically or visually equivalent, the student can describe which comparison was actually available and what remains uncertain. The study lends support to not assuming that sites are interchangeable. It does not supply a mathematical correction from the forearm to another location.

Two images seem to disagree about how visible a scar is

One picture is a close-up that includes little surrounding skin. Another shows a wider area. An honest review distinguishes what each image can support. The close-up can document local details, while the wider view may better show how the scar sits among neighboring skin in the photographed conditions. Neither image identifies scattering independently. A disagreement between them is a reason to inspect how the comparison was framed, not a reason to apply a near-infrared measurement to override what the observer sees.

Frequently asked questions

Did the study measure how light or dark each participant looked?

No. The principal quantity was reduced scattering estimated from patterned-light measurements. The study used Fitzpatrick type to describe the range of participants but did not present the optical coefficients as a visible-light skin tone scale. Reduced scattering, visible appearance, and sun-response classification answer different questions.

Why was 851 nanometers important?

At 851 nanometers, the investigators saw the smallest variation between participants across the locations in their wavelength range and expected less interference from melanin absorption. That made it useful for comparing their scattering estimates between sites. It does not establish that near infrared is the right way to judge a visual tattoo match.

Does the research justify one color for all areas of a person’s skin?

No. If anything, it shows why treating anatomical sites as interchangeable can be a weak assumption. It did not study tattoo colors or provide choices for any participant. Site-specific observation and an evidence-based claim about a treatment are different things; only the former is conceptually informed by this study.

Reference

Phan T, Rowland R, Ponticorvo A, Le BC, Wilson RH, Sharif SA, Kennedy GT, Bernal NP, Durkin AJ. Characterizing reduced scattering coefficient of normal human skin across different anatomic locations and Fitzpatrick skin types using spatial frequency domain imaging. Journal of Biomedical Optics. 2021;26(2):026001. doi:10.1117/1.JBO.26.2.026001.

Read the original study in the Journal of Biomedical Optics

bottom of page