Absorption and reduced scattering coefficients in epidermis and dermis from a Swedish cohort study
Hanna Jonasson, Ingemar Fredriksson, Sara Bergstrand, Carl Johan Östgren, Marcus Larsson, and Tomas Strömberg. Journal of Biomedical Optics. 2023;28(11):115001.
Camo Academy Review
How skin absorbs and scatters light: What 3,809 forearm measurements tell us
Camo Academy Review | Living skin optics, color comparison, and scar camouflage
Short answer
Jonasson and colleagues measured reflected light from the inner forearms of 3,809 adults in a Swedish cohort. They used a layered model to estimate how light is absorbed and scattered in skin at different wavelengths. The model returned different absorption estimates for the upper and lower dermis, but it assumed the same reduced scattering coefficient in all layers. This is useful background for understanding why skin color cannot be read as if it were paint on a flat surface. It is not a study of tattooed scars, and neither its optical estimates nor its instrument sampling depths are instructions for scar camouflage. Read the original study.
Why skin color is more than a surface measurement
Seen from the outside, a scar can look like a patch with a clear boundary and a particular color. That is a reasonable description of what someone sees. It is not a description of how the observed light traveled. Some of it entered the tissue, changed direction, and returned toward the viewer. Some was absorbed along the way. The mix of returned light depends on wavelength and on the tissue through which the light passed. A photograph or visual comparison captures something about the result, but it does not separate those underlying contributions.
This is why optical engineers make a distinction between absorption and scattering. Absorption concerns the removal of light from the traveling beam by the material. Scattering concerns light changing direction as it interacts with structures. The “reduced scattering” quantity used here summarizes scattering in a way that accounts for how strongly light tends to continue forward. It is not a score for the amount of visible texture, nor is it interchangeable with a measure of brightness. The terms are helpful when they name distinct processes rather than serving as technical synonyms for skin appearance.
For scar camouflage, the implication is conceptual. When comparing a mark to nearby skin, the observer sees a relationship between two regions under the light available at the time. Neither region is a uniform colored card. That does not make visual assessment meaningless; it means the conditions and comparison site are part of the evidence. The paper gives a useful example of what it takes to go beyond describing an appearance and estimate underlying optical properties. It does not translate its engineering measurements into a system for choosing tattoo colors.
The design: Reflectance measured in vivo, layers estimated by a model
The project drew on the Swedish CArdioPulmonary bioImage Study, known as SCAPIS. Participants in this analysis were 50 to 65 years old. A probe measured diffuse reflectance at the inner forearm at two distances between the light source and the detector. The researchers analyzed baseline readings and examined light across a range from the visible into the near infrared. This was a large dataset of living forearm skin measured under a specified setup. It was not a sample of scars or a deliberately balanced survey of every skin tone. Primary study methods and cohort description.
The instrument measured the light that returned; it did not independently measure the exact path of light or chemically test every layer. The researchers estimated layer properties with an inverse Monte Carlo method. In ordinary terms, the model simulates how light might travel through a representation of skin, then finds model values that account for the observed readings. There was one modeled epidermal layer and two dermal layers. The model allowed absorption to differ by layer and represented melanin and hemoglobin as contributors. Reduced scattering was shared across the layers in the model, rather than independently estimated for each one.
That last detail is easy to miss in the title. The study can provide findings from a model of layered skin, but it cannot demonstrate that real epidermis and dermis necessarily have exactly the same scattering. The equality was imposed in the model. This is not a defect that makes the data unusable; it is a condition that controls how the result should be read. An estimate that depends on a simplifying assumption is not the same as a direct measurement that verifies the assumption in the people studied.
What the investigators found
The median modeled absorption values differed by wavelength and layer. For example, the upper dermis estimate was 0.094 per millimeter at 475 nanometers and 0.0048 per millimeter at 850 nanometers. The corresponding lower dermis medians were 0.059 and 0.0035 per millimeter. The modeled reduced scattering coefficient was 3.22 per millimeter at 475 nanometers and 1.20 at 850 nanometers. The researchers also reported variation across groups defined by age, sex, and body mass index. These are optical results from this specific model and cohort, not visual thresholds for comparing scars. Published results and reference values.
The numbers are useful because they give readers a sense of how much an optical property can depend on wavelength. A statement about scattering at one wavelength is not a complete characterization of appearance across the spectrum. At the same time, the reported medians are summaries. They do not describe every forearm in the cohort and cannot characterize a single scar by substituting a group value for that scar. Their strongest use is in research or engineering that needs a defined reference under stated conditions.
The two distances between emitter and detector also produced different estimated sampling depths. This gives readers a second lesson about how instruments work: changing where returned light is collected can shift which parts of the tissue contribute most to the signal. Sampling depth in this paper was defined from a modeled distribution of detected light, not by inserting anything into skin or identifying where pigment belongs. Lifting the reported depths out of the study and presenting them as tattoo placement guidance would be a category error.
Where the reference applies and where it does not
The sample size is a strength when describing middle-aged and older adults under the study conditions. The authors describe the majority as having Caucasian skin types, using the paper’s terminology. The cohort does not represent the full variation in pigmentation, age, or anatomy relevant to a scar camouflage library. Nor were different body sites measured to show how closely the values transfer from the inner forearm to other parts of the body. Four thousand well-characterized readings from one kind of site still cannot answer the same questions as measurements distributed across meaningful sites and populations.
Tissue type also matters. A scar may differ from the surrounding skin in appearance, structure, and the features the observer has been asked to judge. This study was not designed to capture the optical properties of a scar or test how pigment and scar tissue together affect returned light. A discussion of why a layered model is plausible does not establish which layers explain a specific visual difference in scarred skin. That work would need appropriate measurements in the tissue of interest.
Finally, the scientific endpoint is distinct from the result a client wants. The researchers did not test whether people perceived a better match between a marked area and surrounding skin, whether that impression held under ordinary lighting, or whether it persisted after medical tattooing. Their study is valuable even though it does not deliver those answers. Keeping the endpoints separate is how its insight into light and tissue becomes a sound part of education instead of a false proof of a service.
Camo Academy interpretation
We read the paper as a reminder that a color comparison should state what was observed and under what conditions. “The scar stands out less in this image” and “we measured a change in the scattering properties of the scar” are vastly different claims. The first may be a relevant aesthetic observation. The second requires appropriate instrumentation, a model, and measurements designed to detect that change. Giving each claim its own language helps prevent a convincing before-and-after picture from being used to prove a mechanism it cannot actually show.
A second takeaway is that measurements carry their definitions with them. Two studies might both use the word “depth” without meaning the same thing. One can mean how far detected light is estimated to have sampled; another might describe a location seen directly in a tissue image. Even within skin optics, models can estimate the same named quantity under different assumptions. We would teach students to read the definition before borrowing the number. That habit is particularly important where a number could sound like a procedural setting even though it is nothing of the kind.
The final lesson concerns what a more direct camouflage study would look like. It would use a meaningful comparison region, include the relevant scar and skin characteristics, and assess whether the visible outcome matters to the participant. Optical measurements could enrich the explanation, but they should not displace the outcome the study actually wants to understand. A patient’s experience, an image, and a modeled tissue coefficient can all contribute. Each becomes more useful when its role is explicit.
Two practical examples in documentation
The same contrast looks different in two records
A student reviews two photos of a scar, one taken under warm indoor illumination and another taken by a window. They notice that the contrast looks different. The study supports a useful conversation about wavelength and conditions, not a conclusion that tissue properties necessarily changed. The two photos record appearances in different conditions, and a reliable review needs to distinguish those conditions from changes observed when the context is comparable. A clear record is more helpful than a guess about whether the scar’s melanin or blood was responsible.
A technical chart lists a depth next to a wavelength
A classmate sees the chart and proposes using that number as a guide for where camouflage pigment should go. This is precisely where the paper needs to be read with its methods. The number describes sampling by a specified optical instrument, under a model of diffuse reflectance. It does not report where a tattoo procedure placed pigment or which location led to a better result. The right lesson is not to ignore measurements, but to tie each measurement to what the researchers actually defined.
Frequently asked questions
Did the study measure skin color or skin optics?
Its main results are estimates of optical properties obtained from diffuse reflectance measurements. They describe how light interacts with a modeled tissue structure, rather than being a skin tone label or a color match score. The distinctions are related, but the output of one cannot automatically stand in for the others.
Does the large cohort make the findings universal?
No. The size gives this paper value as a reference for its defined cohort and measurement site. It does not remedy demographic or anatomical limits. A study of younger people, a wider range of pigmentations, or multiple body sites would answer different questions about how far the estimates can be generalized.
Can the results tell me how a scar camouflage tattoo will look when healed?
No. There was no tattoo intervention and no healed appearance endpoint. The optics help explain why tissue and viewing conditions should not be ignored. They do not establish what an artist should use, when tattooing would be appropriate, or how long a match in one person’s scar will hold.
Reference
Jonasson H, Fredriksson I, Bergstrand S, Östgren CJ, Larsson M, Strömberg T. Absorption and reduced scattering coefficients in epidermis and dermis from a Swedish cohort study. Journal of Biomedical Optics. 2023;28(11):115001. doi:10.1117/1.JBO.28.11.115001.